18-2 The heat pump and structure whose characteristics are shown in Fig. 18-6 are in a region where the design outdoor temperature is -15°C. The compressor of the heat pump uses two cylinders to carry the base load and brings a third into service when needed. The third cylinder has a capacity equal to either of the other cylinders. How much supplementary resistance heat must be available at an outdoor temperature of -15°C? Ans. 5.8 kW. Energy flow rate, kW 24 22 20 18 16 14 12 10 8 00 T New balance point -20 Balance point -10 Additional capacity Heat loss of structure 10 Outdoor-air temperature, "C Figure 18-6 Balance points of heating capacity and heating load. Heating capacity 20

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter48: Cooling Towers And Pumps
Section: Chapter Questions
Problem 13RQ
icon
Related questions
Question

Heat Pumps

18-2 The heat pump and structure whose characteristics are shown in Fig. 18-6 are
in a region where the design outdoor temperature is -15°C. The compressor of the
heat pump uses two cylinders to carry the base load and brings a third into service
when needed. The third cylinder has a capacity equal to either of the other cylinders.
How much supplementary resistance heat must be available at an outdoor temperature
of -15°C? Ans. 5.8 kW.
Energy flow rate, kW
24
22
20
18
16
14
N
10
00
6
4
2
0
1
-20
New balance
point
Balance
point
Additional
capacity
-10
Heat loss of structure
10
Outdoor-air temperature, C
Figure 18-6 Balance points of heating capacity and heating load.
Heating capacity
T
T
20
Transcribed Image Text:18-2 The heat pump and structure whose characteristics are shown in Fig. 18-6 are in a region where the design outdoor temperature is -15°C. The compressor of the heat pump uses two cylinders to carry the base load and brings a third into service when needed. The third cylinder has a capacity equal to either of the other cylinders. How much supplementary resistance heat must be available at an outdoor temperature of -15°C? Ans. 5.8 kW. Energy flow rate, kW 24 22 20 18 16 14 N 10 00 6 4 2 0 1 -20 New balance point Balance point Additional capacity -10 Heat loss of structure 10 Outdoor-air temperature, C Figure 18-6 Balance points of heating capacity and heating load. Heating capacity T T 20
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Available Energy
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning