4. A refrigerant 12 vapour-compression system operates between -10°C and 33°C with saturated liquid on the high side of the expansion valve and saturated vapour entering the compressor whose volumetric efficiency is 88%. An ammonia compression system operates between -35°C and 0°C with saturated liquid entering the expansion valve and saturated vapour entering the compressor whose volumetric efficiency is 85%. The refrigerant -12 evaporator serves as the condenser for ammonia. For the ideal cycle and 10 kW of refrigeration, find a.) the displacement rate of each compressor, and b.) the total actual power required for compression efficiencies of 85 %.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter28: Special Refrigeration Applications
Section: Chapter Questions
Problem 15RQ: Why is two-stage compression popular for extra-low-temperature refrigeration systems?
icon
Related questions
Question

Refrigeration Engineering. Draw the necessary diagrams

4. A refrigerant 12 vapour-compression system operates between -10°C and 33°C with saturated liquid
on the high side of the expansion valve and saturated vapour entering the compressor whose
volumetric efficiency is 88%. An ammonia compression system operates between -35°C and 0°C with
saturated liquid entering the expansion valve and saturated vapour entering the compressor whose
volumetric efficiency is 85%. The refrigerant -12 evaporator serves as the condenser for ammonia. For
the ideal cycle and 10 kW of refrigeration, find a.) the displacement rate of each compressor, and b.)
the total actual power required for compression efficiencies of 85 %.
Transcribed Image Text:4. A refrigerant 12 vapour-compression system operates between -10°C and 33°C with saturated liquid on the high side of the expansion valve and saturated vapour entering the compressor whose volumetric efficiency is 88%. An ammonia compression system operates between -35°C and 0°C with saturated liquid entering the expansion valve and saturated vapour entering the compressor whose volumetric efficiency is 85%. The refrigerant -12 evaporator serves as the condenser for ammonia. For the ideal cycle and 10 kW of refrigeration, find a.) the displacement rate of each compressor, and b.) the total actual power required for compression efficiencies of 85 %.
Expert Solution
steps

Step by step

Solved in 9 steps with 1 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning