A long cylinder of 30-mm diameter, initially at a uniform temperature of 1100 K, is suddenly quenched in a large, constant- temperature oil bath at 350 K. The cylinder properties are k = 1.7 W/m-K, c = 1600 J/kg-K, and p = 400 kg/m³, while the convection coefficient is 54 W/m².K. Physical Properties Mathematical Functions Step 1 When deciding if the lumped capacitance method can be used, what is the value of the Biot number? Bic Save for Later Using multiple attempts will impact your score. 100% score reduction after attempt 6 Step 2 When using the one-term approximation for transient 1-D conduction, what is the value of the applicable Biot number? Use Table 5.1. Bi = Attempts: 0 of 7 used Submit Answer i

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter1: Basic Modes Of Heat Transfer
Section: Chapter Questions
Problem 1.68P
icon
Related questions
Question

 Assume the Fourier number, Fo, is greater than or equal to 0.2 (note that you still need to calculate the Biot number, and possibly a second Biot number).

A long cylinder of 30-mm diameter, initially at a uniform temperature of 1100 K, is suddenly quenched in a large, constant-
temperature oil bath at 350 K. The cylinder properties are k = 1.7 W/m-K, c = 1600 J/kg-K, and p = 400 kg/m³, while the
convection coefficient is 54 W/m².K.
Physical Properties Mathematical Functions
Step 1
When deciding if the lumped capacitance method can be used, what is the value of the Biot number?
Bic = i
Save for Later
Using multiple attempts will impact your score.
100% score reduction after attempt 6
Step 2
Attempts: 0 of 7 used Submit Answer
When using the one-term approximation for transient 1-D conduction, what is the value of the applicable Biot number? Use Table
5.1.
Bi = i
Transcribed Image Text:A long cylinder of 30-mm diameter, initially at a uniform temperature of 1100 K, is suddenly quenched in a large, constant- temperature oil bath at 350 K. The cylinder properties are k = 1.7 W/m-K, c = 1600 J/kg-K, and p = 400 kg/m³, while the convection coefficient is 54 W/m².K. Physical Properties Mathematical Functions Step 1 When deciding if the lumped capacitance method can be used, what is the value of the Biot number? Bic = i Save for Later Using multiple attempts will impact your score. 100% score reduction after attempt 6 Step 2 Attempts: 0 of 7 used Submit Answer When using the one-term approximation for transient 1-D conduction, what is the value of the applicable Biot number? Use Table 5.1. Bi = i
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning