An inductive AC load draws 13.4 amps of current at a voltage of 208 volts. The phase shift between line voltage and line current is measured with an oscilloscope, and determined to be 23 Degrees. Calculate the following: • Apparent power (S) = • True power (P) = • Reactive power (Q) = • Power factor = An electrician suggests to you that the lagging power factor may be corrected by connecting a capacitor in parallel with this load. If the capacitor is sized just right, it will exactly offset the reactive power of the inductive load, resulting in zero total reactive power and a power factor of unity (1). Calculate the size of the necessary capacitor in Farads, assuming a line frequency of 60 Hz.

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter7: Alternating Current, Power Distribution, And Voltage Systems
Section: Chapter Questions
Problem 8RQ
icon
Related questions
Question
i.
ii.
Draw a marine electrical distribution system diagram to the best of your ability.
Identify some of the basic components.
An inductive AC load draws 13.4 amps of current at a voltage of 208 volts. The phase
shift between line voltage and line current is measured with an oscilloscope, and
determined to be 23 Degrees. Calculate the following:
• Apparent power (S) =
• True power (P) =
• Reactive power (Q) =
• Power factor =
An electrician suggests to you that the lagging power factor may be corrected by
connecting a capacitor in parallel with this load. If the capacitor is sized just right, it
will exactly offset the reactive power of the inductive load, resulting in zero total
reactive power and a power factor of unity (1). Calculate the size of the necessary
capacitor in Farads, assuming a line frequency of 60 Hz.
Transcribed Image Text:i. ii. Draw a marine electrical distribution system diagram to the best of your ability. Identify some of the basic components. An inductive AC load draws 13.4 amps of current at a voltage of 208 volts. The phase shift between line voltage and line current is measured with an oscilloscope, and determined to be 23 Degrees. Calculate the following: • Apparent power (S) = • True power (P) = • Reactive power (Q) = • Power factor = An electrician suggests to you that the lagging power factor may be corrected by connecting a capacitor in parallel with this load. If the capacitor is sized just right, it will exactly offset the reactive power of the inductive load, resulting in zero total reactive power and a power factor of unity (1). Calculate the size of the necessary capacitor in Farads, assuming a line frequency of 60 Hz.
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning