Bolted and Riveted Connections 1. From the bolted connection shown, the diameter of bolts is 18mm0 with the hole diameter equal to 3mm bigger than the bolt, the angular section is 100 x 75 x 8 mm, with an area of 1340 mm2. Thickness of the gusset plate is 9mm. The gusset plate and angle arc A36 steel with Fy = 250 MPa and F₁400 MPa. a. Determine the tensile capacity of the connection based on gross area. b. Determine the tensile capacity of the connection based on effective net area using a reduction factor of 0.85. c. Determine the tensile capacity of the connection based on gross area. 100 x 75 x 8 mm 9 mm gusset plate 100 31.25 31.25 T

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

Please answer as soon as possible

Bolted and Riveted Connections
1. From the bolted connection shown, the diameter of bolts is 18mm0 with the hole diameter equal to
3mm bigger than the bolt, the angular section is 100 x 75 x 8 mm, with an area of 1340 mm2.
Thickness of the gusset plate is 9mm. The gusset plate and angle arc A36 steel with F, = 250 MPa
and F₁ = 400 MPa.
a. Determine the tensile capacity of the connection based on gross area.
b. Determine the tensile capacity of the connection based on effective net area using a reduction
factor of 0.85.
c.
Determine the tensile capacity of the connection based on gross area.
100 x 75 x 8 mm
9 mm gusset plase
100
31.25
31.25
T
Transcribed Image Text:Bolted and Riveted Connections 1. From the bolted connection shown, the diameter of bolts is 18mm0 with the hole diameter equal to 3mm bigger than the bolt, the angular section is 100 x 75 x 8 mm, with an area of 1340 mm2. Thickness of the gusset plate is 9mm. The gusset plate and angle arc A36 steel with F, = 250 MPa and F₁ = 400 MPa. a. Determine the tensile capacity of the connection based on gross area. b. Determine the tensile capacity of the connection based on effective net area using a reduction factor of 0.85. c. Determine the tensile capacity of the connection based on gross area. 100 x 75 x 8 mm 9 mm gusset plase 100 31.25 31.25 T
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Asphalt binders and mixtures
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning