Choose the correct answer of the following questions: 1. If the secondary power of a transformer is increased by 50% then the magnetic flux (p) passing in the magnetic core will: a. Increase by 50% c. Increases by 25% b. Decreases by 50% d. None of the above 2. In a A-Y connection three-phase transformer of K turn ratio, the secondary line voltage is: a. VL2 =VL1 b. V₁2 = VL1 c. VL2 = KVL1 d. V₁2 = VL1 3. Two 400kVA single-phase transformers work as V-V (open-delta) connection, supply a 1200 kVA load. The kVA supplied by each transformer is: a. 400kVA of each b. Sharing the load equally d. 300kVA of each c. 693kVA of each 4. In an auto-transformer of K transformation ratio, the power transferred inductively from the primary side to the secondary side is equal to: a. P = (1-K) Pin b. P = (K) Pin d. P = K² Pin c. P = (1+K) Pin 5. In a single-phase transformer, the percentage resistance drops is 1.0% and percentage reactance drop is 5.0%, the percentage voltage regulation when the power factor 0.8 leading is: a. 3% b. -2.2% d. 3.8% c. -3.4%
Choose the correct answer of the following questions: 1. If the secondary power of a transformer is increased by 50% then the magnetic flux (p) passing in the magnetic core will: a. Increase by 50% c. Increases by 25% b. Decreases by 50% d. None of the above 2. In a A-Y connection three-phase transformer of K turn ratio, the secondary line voltage is: a. VL2 =VL1 b. V₁2 = VL1 c. VL2 = KVL1 d. V₁2 = VL1 3. Two 400kVA single-phase transformers work as V-V (open-delta) connection, supply a 1200 kVA load. The kVA supplied by each transformer is: a. 400kVA of each b. Sharing the load equally d. 300kVA of each c. 693kVA of each 4. In an auto-transformer of K transformation ratio, the power transferred inductively from the primary side to the secondary side is equal to: a. P = (1-K) Pin b. P = (K) Pin d. P = K² Pin c. P = (1+K) Pin 5. In a single-phase transformer, the percentage resistance drops is 1.0% and percentage reactance drop is 5.0%, the percentage voltage regulation when the power factor 0.8 leading is: a. 3% b. -2.2% d. 3.8% c. -3.4%
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.9P
Related questions
Concept explainers
KVL and KCL
KVL stands for Kirchhoff voltage law. KVL states that the total voltage drops around the loop in any closed electric circuit is equal to the sum of total voltage drop in the same closed loop.
Sign Convention
Science and technology incorporate some ideas and techniques of their own to understand a system skilfully and easily. These techniques are called conventions. For example: Sign conventions of mirrors are used to understand the phenomenon of reflection and refraction in an easier way.
Question
i need the last 2 (4+5)
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning