For a refrigerator or air conditioner, the coefficient of performance K (often denoted as COP) is the ratio of cooling output Qc to the required electrical energy input W], both in joules. The coefficient of performance is also expressed as a ratio of powers, K= \Qc\/t \W\/t where Qc\/t is the cooling power and W/t is the electrical power input to the device, both in watts. Y Part A ▾ For a home air conditioner, K is generally determined for a 35°C outside temperature and an 27°C return air temperature. Calculate K for a Carnot device that operates between 35°C and 27°C. K= Submit Part B cost= Submit 195) ΑΣΦ ▾ Part C You have an air conditioner with of 3.2. Your home on average requires a total cooling output of Qc = 2.1 x 10¹0 J per year. If electricity costs you 12.5 pence per kW-h. how much do you spend per year, on average, to operate your air conditioner? (Assume that the unit's COP accurately represents the operation of your air conditioner. A seasonal coefficient of performance (SCOP) is often used. The SCOP is calculated over a range of outside temperatures to get a more accurate seasonal average.) Express your answer in pounds. [5] ΑΣΦ 1 → Ć Request Answer savings = Request Answer → C 197| ΑΣΦΑ ? You are considering replacing your air conditioner with a more efficient one with of K = 4.3. Based on the K. how much would that save you on electricity costs in an average year? Express your answer in pounds. → ? GBP ? GBP
For a refrigerator or air conditioner, the coefficient of performance K (often denoted as COP) is the ratio of cooling output Qc to the required electrical energy input W], both in joules. The coefficient of performance is also expressed as a ratio of powers, K= \Qc\/t \W\/t where Qc\/t is the cooling power and W/t is the electrical power input to the device, both in watts. Y Part A ▾ For a home air conditioner, K is generally determined for a 35°C outside temperature and an 27°C return air temperature. Calculate K for a Carnot device that operates between 35°C and 27°C. K= Submit Part B cost= Submit 195) ΑΣΦ ▾ Part C You have an air conditioner with of 3.2. Your home on average requires a total cooling output of Qc = 2.1 x 10¹0 J per year. If electricity costs you 12.5 pence per kW-h. how much do you spend per year, on average, to operate your air conditioner? (Assume that the unit's COP accurately represents the operation of your air conditioner. A seasonal coefficient of performance (SCOP) is often used. The SCOP is calculated over a range of outside temperatures to get a more accurate seasonal average.) Express your answer in pounds. [5] ΑΣΦ 1 → Ć Request Answer savings = Request Answer → C 197| ΑΣΦΑ ? You are considering replacing your air conditioner with a more efficient one with of K = 4.3. Based on the K. how much would that save you on electricity costs in an average year? Express your answer in pounds. → ? GBP ? GBP
Chapter1: Temperature And Heat
Section: Chapter Questions
Problem 101P: Many decisions are made on the basis of the payback period: the time it will take through savings to...
Related questions
Question
Needs Complete solution with 100 % accuracy.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 5 steps with 5 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Recommended textbooks for you