If a 425 sin (wt + 45o) V supplies a current of 60 cos(wt - 350) A, Determine the power in the circuit, the reactive power, the apparent power, the reactive factor, and the power factor.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.7P: Let a 100V sinusoidal source be connected to a series combination of a 3 resistor, an 8 inductor,...
icon
Related questions
Question

If a 425 sin (wt + 45o) V supplies a current of 60 cos(wt - 350) A, Determine the power in the circuit, the reactive power, the apparent power, the reactive factor, and the power factor.

 

 Answer: 0.9848 Leading, 0.1737 Capacitive, 12556.2 W, 2214.7 V Ars Capacitive, 12750 V A