Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature resistance of 0.05 Q. Each of generators G1, G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz, respectively The no-load frequency of each generator is set to 52.4 Hz. The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first. At what system frequency does this limit occur? Select one: O a. fays = 48.97 Hz O b. fsys = 48.25 Hz c. fsys = 49.22 Hz O d. None

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.3MCQ: The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of...
icon
Related questions
icon
Concept explainers
Question
Three identical steam-turbine generators G1, G2, and G3 are operating in parallel.
Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature
resistance of 0.05 Q.
Each of generators G1 , G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz,
respectively The no-load frequency of each generator is set to 52.4 Hz.
The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first.
At what system frequency does this limit occur?
Select one:
O a. fsys = 48.97 Hz
O b. fsys = 48.25 Hz
c. fsys = 49.22 Hz
O d. None
Transcribed Image Text:Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 21 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with synchronous reactance of 2 Q and an armature resistance of 0.05 Q. Each of generators G1 , G2, and G3 has a characteristic power-frequency slope of 5.2 MW/Hz , 4.5 MW/Hz, and 4.9 MW/Hz, respectively The no-load frequency of each generator is set to 52.4 Hz. The load increases with no changes in the settings of the no-load frequencies, until a generator reaches its maximum rated power first. At what system frequency does this limit occur? Select one: O a. fsys = 48.97 Hz O b. fsys = 48.25 Hz c. fsys = 49.22 Hz O d. None
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning