Analysis 5 ppm Fe (III) Is done with a hew analysis method. The experiment is repeated 3 times, and the average iron ion concentration is determined as 4.7 ppm. The standard deviation, s = 0.1, is calculated according to the results of the three experiments. Does the new analysis method contain systematic errors at a 95% confidence level? (Choose the t value from the Table) t values Degrees of freedom 95% CL 12.7 4.3 3.18 2.78 O a. A systematic error exists O b. Only random error exists
Q: The additive in gasoline was measured 16 times to give a standard deviation of 0.24. The standard…
A: GivenNo of times measured = N = 16Standard deviation = S.D. = 0.24Standard deviation of the mean is…
Q: A new method for the analysis of mercury was in an ore sample was tested and obtained the following…
A: Given data: x = 12.72 % s = 0.08746 Accepted Method Results # of samples = 6 Average = 12.63% Hg…
Q: d) The following data was obtained from the determination of lead, Pb in a wastewater sample. Four…
A: The solution is attached below-
Q: D. 10 mL volumetric flask Mass of volumetric flask Volume of water measured in each trial 10:00mL…
A: A question based on properties of liquid that is to be accomplished.
Q: 2. Students measured and recorded the mass of a rock four times. The true mass of the rock is known…
A: Solved in step 2
Q: Molarity trail 1 0.0366 trail 2 0.0373 trail 3 0.0370 Calculate the standard deviation. Calculate…
A:
Q: For the given data set: [6.7, 7.3, 7.5, 7.2, 7.9, and 7.1] Determine the outlier using Grubbs test.…
A:
Q: Expenm 1. Why should weighing data or any other measurement data be recorded immediately in…
A: Solution
Q: Analysis of several plant-food preparations for potassium ion yielded the following data: Sample…
A:
Q: Analysis of several plant-food preparations for potassium ion yielded the following data: Sample…
A: As per our company guidelines we are supposed to answer the first question only as it is a lengthy…
Q: Classify whether the following is an Instrumental error, Method error, Personal error, Indeterminate…
A: Explanation of terms involved Instrumental error occurs when the calibration of an instrument is…
Q: Use the "Statistics" function of your calculator to find the mean and standard deviation for the…
A: Ans. Mean and Standard deviation according to statistic calcultor Mean = 68.7 inch Standard…
Q: Scenario: The student is asked to measure 9.20 mL of potassium permanganate solution using a 10-mL…
A: A numerical problem based on quantitative analysis, which is to be accomplished.
Q: . A student performed four trials to determine the molar mass of butane in Gas Laws lab. The average…
A:
Q: The picture says my question
A: #1. Your answer to 1 is right.
Q: In a gravimetric chloride analysis, it was found that 0.82g AgCl was obtained from an unknown that…
A: Since we only answer up to 3 sub-parts, we’ll answer the first 3. Please resubmit the question and…
Q: Date Wednesday, November 20, 2019 9:59 AM 1017 100 95- 9어 85 8어 75 3277.4 7어 1448.4 65 1367.9 2936.2…
A: Some important IR peaks of 4-tert-butyl cyclohexanol are discussed below : A. Broad medium peak at…
Q: Estimate the absolute standard deviation (or uncertainty) for the results of the following…
A: a. y = 2.998(±0.002) - 3.98 (±0.15) + 9.035 (±0.002) = 8.0531 where 'u' is the Absolute standard…
Q: wo students measured the density of water three times each. Their results are shown below. Trial…
A:
Q: An analysis of city drinking water for total hardness was done by two students in the laboratory and…
A: Note: Since you have posted question with multiple parts, we will solve only first part for you. To…
Q: A set of samples from an abandoned industrial site detected a suspected groundwater contaminant at a…
A:
Q: A volumetric calcium analysis on samples of the blood serum of a patient believed to be suffering…
A: “Since you have posted a question with multiple sub-parts, we will solve first three sub-parts for…
Q: How many sig figs should the result of the following have? Xs are digits that are purposefully not…
A: In the question 1. we have to determine the significant figure from the given equation which has…
Q: A sample is analyzed 10 times for cobalt concentration with a mean of 10.32 ppm and an absolute…
A: The size of the sample is 10. The mean value and standard deviation of the sample is 10.32 ppm and…
Q: Increasing the number of measurements will decrease the standard deviation increase the systematic…
A: Error formula is the absolute value of the difference of the measured value and the actual value…
Q: An analysis of a sample containing mercury was performed using a standard procedure and a new…
A: An F-test is based on measurements of standard deviation S.The various steps involved in the test…
Q: 2. A chemist performed an experiment to determine the melting point of sodium chloride with the…
A: Mean = (sum of all measurements)/ number of measurements. Percent error =( |actual value - expected…
Q: Measurements of boiling temperatures of samples of a liquid (°C) are given below: 78.4 79.0 78.8…
A: The mean is equal to the sum of all the data values divided by the count of values in the data set.…
Q: Measuring the proportional response of an analyte to things such as light or an electric current is…
A: Option A is correct answer.
Q: 8) Two different analytical methods are compared for determining Ca. The following are two sets of…
A:
Q: Suppose a certain species of fawns between 1 and 5 months old have a body weight that is…
A: mean μ =28.6 kgstandard deviation σ= 3.7 kgz > 2.7z = (x-μ)/σ2.7< (x-28.6)/3.72.7×3.7 < x -…
Q: Perform the outlier test at 95% confidence level to detect any in the given data. Calculated Q…
A: Given data: Coin Mass, g 1 5.3456 2 5.2893 3 5.3309 4 5.3594 5 5.2908 6 5.3196 7…
Q: Construct a calibration curve: (a) Subtract the blank value (9.1) from all other values (this means…
A: (a) Slope = 874.05 ± 10.62 Intercept = - 29.61 ± 9.65 Calculation table vol %…
Q: 3. Two laboratory staff titrated a 50.00 mL of hydrochloric acid with an unknown concentration with…
A: Smaller the standard deviation of a data set, more precise is the measurement. A more accurate…
Q: Five blood samples got these results: 0.752, 0.756, 0.752, 0.751, 0.760 ppm The standard deviation…
A:
Q: A method of analysis yields masses of gold that are low by 0.4 mg. Calculate the percent relative…
A: We’ll answer the first question since the exact one wasn’t specified. Please submit a new question…
Q: 7-6. The last result in each set of data in Problem 7-4 may be an outlier. Apply Q test (95%…
A: By applying Q-test we can easily find whether the data point in question is an outlier or not. If…
Q: A pharmacist is asked to weigh 140 mg of lidocaine powder on the standard balance. The maximum…
A: Given that, Sensitivity requirement = 3mg Acceptable error = 5% To be calculated, Minimum weighable…
Q: y = log 3.9201 (±0.0006)×10-3
A: Solution - According to the question - Given - Let us calculate the numerator terms: [ simplify]…
Q: In a particular trial, a student got a value for R of 0.083. Calculate the percent deviation of this…
A: Percent deviation is given by:% deviation = Experimental value - Accepted valueAccepted…
Q: The results obtained by two analysts for the lead content of samples obtained at different certified…
A:
Q: Convert your average ppm concentration (and standard deviation) of Ca from the ISE measurements…
A: "Since there are multiple sub-parts in this question and it is not mentioned that which one has to…
Q: standard deviation of concentration (g/mL)
A: Given information: X= cesium iodide
Q: Given the data obtained from the voltmeter ranking of metals, calculate the standard deviation for…
A: Given: The given data is:
Q: Certified Reference Material (CRM), GSS-5, is certified to contain 40.67 ± 3.33 mg/kg of Ni in soil.…
A:
Q: You have a stock solution certified by a manufacturer to contain 220.0 + 0.4 ug So /ml. You would…
A: Method A: Dilution of 10.00 mL (transfer pipet) 215.0 g/mL stock solution to 100 mL (vloumetric…
Q: The length of one pencil is measured with a ruler, the following measurements are obtained; 5.49…
A: Arranging the obtained length in arranging order we get: 3.28 , 5.34 , 5.38 , 5.41 , 5.49 Finding…
Q: Estimate the absolute deviation(or uncertainty) for the results of the following calculations. Round…
A: Thank u for your question, answer is attached below.
Q: Quantitative analysis student Jon analyzed an ore sample for its lead content and obtained a mean of…
A: Given: obtained value- 4.75% certified value- 4.50% To find: (a) percent error (b) percent accuracy…
Step by step
Solved in 2 steps with 2 images
- A 0.1475-M solution of Ba(OH)2 was used to titrate the acetic acid (60.05 g/mol) in a dilute aqueous solution. The following results were obtained. (See attached image)(a) Calculate the mean w/v percentage of acetic acid in the sample.(b) Calculate the standard deviation for the results.(c) Calculate the 90% confidence interval for the mean.(d) (d) At the 90% confidence level, could any of the results be discarded?A student creates a calibration plot for serial dilutions of Cu(NO3)2. A graph of concentration in M (x-axis) versus absorbance (y-axis) gives a linear trendline of y = 0.345x - 0.11. c.) How many grams of Cu(NO3)2 are present in 100 grams of solution? How many grams of water?1. A solution is known to contain 38.04 ± 0.03 mM KCl, and you have taken an aliquot of this solution using a pipette calibrated to deliver 20.013 ±0.006 mL. Determine the number of moles of KCl that are delivered in the aliquot, including the absolute uncertainly in that value. 2. You deliver the aliquot taken in problem 1 into a volumetric flask with a volume of 250.00 mL ± 0.02 % and dilute the solution to volume in the flask using Dl water. What is the concentration of KCl in this flask, report your answer with the absolute uncertainty. 3. Tabulated below are replicate titration volumes for an analysis. What is the error (both absolute and percent) for the average titration volume?
- 7) The homogeneity of the chloride level in a water sample from a lake was tested by an analyst. Below are the concentration in parts per million (ppm) of Cl: 27.32, 27.22, 27.21, 27.24, 27.20 i. Determine the mean and median. ii. Calculate the confidence limit at 90%. iii. Identify a possible outlier and use the Q-test to determine whether it can be retained or rejected at 90% confidence levelDoes it possible to use gravimetric analysis to quantiify certain parameters as indicators of quality in squash soup? If yes, please explain the processAs part of this experiment you will need to determine the concentrations of Fe* and SCN ions present in test tubes 1-9. These values can be calculated using the volumes and concentrations provided in Tables 1 and 2 of the Equilibrium Lab - Procedure and the dilution equation (M,V1 = M2V2). Note: the solutions provided in the lab, and therefore the tables in the lab document, are the compounds used to prepare the solution. You must determine the concentration of the ions based on how these compounds díssociate in solution Complete the following table by filling the the calculated initial concentrations of each substance. Be sure to: Pay attention to significant figures • Round appropriately Use decimal notation (not scientific) Do not include units Test Initial [Fe3*] (M) Initial [SCN'] (M) Tube 1 3 4. 6. 7 8. 2.
- The molarity of a solution is determined by four separate titrations or replicates, where the obtained data was 0.4120, 0.4920, 0.3920, and 0.4320 M. Calculate the standard error of the mean for the above data. O 0.00185 O 0.02160 O 0.43200 O 0.04320 O 0.01080You are preparing a 100.0 mL standard solution needed for titration analysis. The NaOH (40 g/mol) pellets are measured to be 0.5341 g in a balance with acceptable uncertainty of +0.001 g. Mass of the pellets is recorded after taring the container. The pellets are put in a beaker and added with 50 ml distilled water measured by a graduated cylinder. The solution is then quantitatively transferred to a 100-mL volumetric flask with uncertainty of ±0.08 mL and diluted to a 100-mL mark. What is the concentration (M) of the solution and estimate its uncertainty by propagation? Assumption: There is no uncertainty in molar mass. Express your answer as C+/- u M.2- 150 mg of NazC2O4 containing solution is titrated with a KMNO4 solution with the corretion factor 1.03. The consumption of KMNO4 is found as 29 mL. Find the theoretical molarity (M) and real concentration (Mreal) of the KMNO4 solution.
- A solution of HCl was titrated against sodium carbonate. What is the average normality of acid in the given data? (MW Na₂CO3 = 106) T2 0.3479 0.3562 0.3042 Weight (g) Initial V (ml) 0.80 1.60 35.20 36.70 39.80 Final V (mL) Vol HCl used (mL) 35.10 39.40 N of HCl (eq/L) 0.1954 0.1870 Average N of HCl (eq/L)A 15.00 g sample containing mixed alkali and other inert components was dissolved and diluted to 300 mL with water. A 20 mL aliquot was titrated with 5.02 mL of 0.5352 M HCl to reach PHP endpoint. Another 20 mL aliquot was titrated to the BCG endpoint, using up 18.87 mL of titrant in the process. Note: Answer in two decimal places only. If there is no answer, type in 0.00. Use the molar masses 105.989 ?/??l ??2cO3 and 84.007 g/mol NaHCO3 indicated. The volume of titrant needed to neutralize NaOH is _________ mL.The volume of titrant needed to neutralize Na2CO3 is _____________ mL.The volume of titrant needed to neutralize NaHCO3 is _____________ mL. The mass of NaOH is ___________ g.The mass of Na2CO3 is __________ g.The mass of NaHCO3 is __________ g. The percent weight of NaOH is __________ %.The percent weight of Na2CO3 is __________ %.The percent weight of NaHCO3 is __________ %.A phamacist reconstituted a vial of 750 mg Cefuroxime Sodium Powder for Injection with 6mL of sterile water for injection. The reconstituted solution was dark amber-colored solution. The package insert states that solution colors range from clear to yellow depending on concentration, diluent, and storage conditions. The pharmacist was then hesitant to give the patient the solution due to its unusual dark color. Five portions were taken from a batch of cefuroxime sodium. Prior to testing in the instrument, each part was subjected to one of the following conditions: Conditions Specifications Temperature Portion 1: 8°C ± 2°C Portion 2: 30°C ± 2°C Portion 3: 40°C ± 2°C Light Portion 4: Kept in the dark Portion 5: Exposed to direct sunlight a. Which form of the product – the powder for injection, the reconstituted product, or both – will you subject to the following conditions and why? b. Will you also expose the reference standard of cefuroxime sodium to the same…