Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
9th Edition
ISBN: 9781259989452
Author: Hayt
Publisher: Mcgraw Hill Publishers
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 12, Problem 12E
(a)
To determine
The total power lost in the two lines for the given condition.
(b)
To determine
The average power delivered to the load for the given condition.
(c)
To determine
The power factor of the load for the given condition.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
2.45 Two balanced Y-connected loads, one drawing 10 kW at 0.8 power factor
lagging and the other 15 kW at 0.9 power factor leading, are connected
in parallel and supplied by a balanced three-phase Y-connected, 480-V
source. (a) Determine the source current. (b) If the load neutrals are
connected to the source neutral by a zero-ohm neutral wire through an
ammeter, what will the ammeter read?
Is it possible to measure the phase-shift angle in an AC single-phase circuit by an indirect method using an ammeter and a voltmeter?
- Yes, but an instrument must be added to measure the active resistance of the load.
- Yes, but an instrument must be added to measure the active power dissipated by the load.
- Yes, but an instrument must be added to measure the frequency.
Q4/For the three-phase power network shown in Figure. the various components are:
GI: 100 MVA, 0.30 pu reactance.
G2: 60 MVA, 0.18 pu reactance.
Transformers (cach): 50 MVA, 0.10 pu reactance.
Inductive reactor X: 0.20 pu on a base of 100 MVA.
Lines (each): 80 ohms (reactive); neglect resistance.
with the network initially unloaded and a line voltage of 110 kV, a symmetrical short circuit
occurs at midpoint E of line 2. Calculate the short circuit MVA to be interrupted by the circuit
breakers A and B at the ends of the line.
T3
38
L1
L2
G2
Bas
12
T4
Bus
Chapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Ch. 12.1 - Let and . Find (a) Vad; (b) Vbc; (c) Vcd.Ch. 12.2 - Prob. 2PCh. 12.2 - Modify Fig. 12.9 by adding a 1.5 resistance to...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - Three balanced Y-connected loads are installed on...Ch. 12.4 - Each phase of a balanced three-phase -connected...Ch. 12.4 - Prob. 8PCh. 12.5 - Determine the wattmeter reading in Fig. 12.24,...Ch. 12.5 - Prob. 10P
Ch. 12 - Prob. 1ECh. 12 - Prob. 2ECh. 12 - Prob. 3ECh. 12 - Describe what is meant by a polyphase source,...Ch. 12 - Prob. 5ECh. 12 - Prob. 6ECh. 12 - Prob. 7ECh. 12 - Prob. 8ECh. 12 - Prob. 9ECh. 12 - Prob. 10ECh. 12 - The single-phase three-wire system of Fig. 12.31...Ch. 12 - Prob. 12ECh. 12 - Referring to the balanced load represented in Fig....Ch. 12 - Prob. 14ECh. 12 - Prob. 15ECh. 12 - Consider a simple positive phase sequence,...Ch. 12 - Assume the system shown in Fig. 12.34 is balanced,...Ch. 12 - Repeat Exercise 17 with Rw = 10 , and verify your...Ch. 12 - Prob. 19ECh. 12 - Prob. 20ECh. 12 - Prob. 21ECh. 12 - Prob. 22ECh. 12 - A three-phase system is constructed from a...Ch. 12 - Prob. 24ECh. 12 - Each load in the circuit of Fig. 12.34 is composed...Ch. 12 - Prob. 26ECh. 12 - Prob. 27ECh. 12 - A three-phase load is to be powered by a...Ch. 12 - For the two situations described in Exercise 28,...Ch. 12 - Prob. 30ECh. 12 - Prob. 31ECh. 12 - Prob. 32ECh. 12 - Repeat Exercise 32 if Rw = 1 . Verify your...Ch. 12 - Prob. 34ECh. 12 - Prob. 35ECh. 12 - Prob. 36ECh. 12 - A wattmeter is connected into the circuit of Fig....Ch. 12 - Find the reading of the wattmeter connected in the...Ch. 12 - (a) Find both wattmeter readings in Fig. 12.39 if...Ch. 12 - Circuit values for Fig. 12.40 are , , , , . Find...Ch. 12 - Prob. 41ECh. 12 - Prob. 42ECh. 12 - (a) Is the load represented in Fig. 12.41...Ch. 12 - Prob. 44E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Consider two interconnected voltage sources connected by a line of impedance Z=jX, as shown in Figure 2.27. (a) Obtain expressions for P12 and Q12. (b) Determine the maximum power transfer and the condition for it toarrow_forwardThree single-phase transformers, each rated 10MVA,66.4/12.5kV,60Hz, with an equivalent series reactance of 0.1 per unit divided equally between primary and secondary, are connected in a three-phase bank. The high-voltage windings are V-connected and their terminals are directly connected to a 115-kV three-phase bus. The secondary terminals are all shorted together. Find the currents entering the high-voltage terminals and leaving the low-voltage terminals if the low-voltage windings are (a) Y-connected and (b) - connected.arrow_forwardPower Transmission and Distribution Discuss the advantages and disadvantages of single-phase and three-phase systemarrow_forward
- A current is measured at the neutral ground of a star load, of equal impedances in all three phases. Which of the following conditions is NOT possible?A) The currents in the three phases are equal in magnitude and angle.B)One phase of the supply conductors was left in open circuit.C) The line-to-neutral voltages in the load are equal in magnitude and with 120° phase shifts between them.D) None of the abovearrow_forwarda. i. Why do power systems operate in an interconnected arrangement? ii. How is the frequency controlled in a power system? iii. What is meant by the stiffness of a power system? b. Two 50 Hz power systems are interconnected by a tie-line, which carries 1000 MW from system A to system B, as shown below. After the outDage of the line shown in the figure, the frequency in system A increases to 50.5 Hz, while the frequency in system B decreases to 49 Hz. i. Calculate the stiffness of each system. ii. If the systems operate interconnected with 1000 MW being transferred from A to B, calculate the flow in the line after outage of a 600 MW generator in system B. 1000 MW A Вarrow_forwardQ2) A 13.2-kV single-phase generator supplies power to a load through a transmission line. The load's impedance is Zload = 500 236.87° ohm, and the transmission line's impedance is Zline = 60 253.1° ohm. To reduce transmission line losses to 0.0103 of its losses without using the transformers design and use two transformers T1 between the generator and the transmission line and T2 between the transmission line and the load.arrow_forward
- Q2. A group of engineers are designing a 400-kV transmission line. They are going to study the transient over voltages, but the due is so close and they need to focus on the most effective event to secure the line insulations against the short-time transients. Which one of the below events you will suggest them study carefully? a) Lightning b) Air switching c) SF6 switchingarrow_forwardThree houses in a small village are supplied from a 400 V 50 Hz three-phase pole-mounted transformer through a four-wire overhead line. Each house is connected between a different line and neutral. Unfortunately, the neutral wire in the overhead line is accidently broken just after the transformer and before the house connections. Given that the house on line 1 has a 10.5 kW shower running, the house on line 2 has a 2.5 kW cooker oven switched on and the house on line 3 is using a 2 kW electric kettle, what voltage will each house receive?arrow_forwardProblem 1 - Series en Parallel AC networks [19] Look at the circuit in Figure 1 and determine the following: (a) Total Admittance. (b) Total Impedance. (c) Total Current (l:). (d) Current (I1) through impedance Z2. (e) Current (12) through impedance Z3. (f) Current (I3) through impedance Z4. (g) Is this an inductive or capacitive circuit? A. B Zs 220V;50HZ Figure 1 (h) Voltage across Z1. (i) Voltage across A and B. G) Voltage across Zs. Z1 = 3 + j5 ohm Z2 = 10 + jo ohm Z3 = 5 + j15 ohm Z4 = 10 – j30 ohm Zs = 20 – j30 ohm Admittance and Impedance in rectangular notation. All currents and voltage in polar notation. Take voltage as reference.arrow_forward
- A- A 3-ph, double circuit O.H.T.L, 320 kV, 340 km, 50 Hz has a configuration as shown in the figure below where each phase in the double circuit has a double bundle with a spacing of d cm between the two conductors in the bundle where d is the last two digits (from right) of your registration number (i.e for the student that has a registration mumber 202112396, d= 96). Each conductor in the bundle has a diameter of 0.135 ft and a geometric mean radius (Ds = 1.6 cm). Calculate: 1- Inductance per phase per km. 2- Total inductive reactance. 3- This T.L. is required to supply 240 MVA at 0.86 lag P.f. at 320 kV, assuming that this load is divided equally between these two circuits, find the voltage drop across this T.L (ignore capacitive effect in the calculation). 4- What may happen if we replace the location of a' and c' bundles. Discuss your answer. 5- Suggest a way to ređuce the value of the inductance. Verify your suggestion. -8 m 3m 3m 8 m 11 marrow_forwardA workshop from a 231/400 V transformer center with a 3-phase and four-conductor underground cablefed. The resistance of the phase conductors is 0.035 ohms and the resistance of the neutral conductors is 0.05 ohms.25 kVA at 0.8 reverse power factor from R phase of the supply line, 0.8 forward power factor from S phase 15Fully ohmic loads of 10 kVA are drawn from kVA and T phases.(a) Find the currents flowing through the phase conductors and neutral conductors.(b) Voltage drops between the transformer substation and the workshop and at the load terminals.calculate the voltages(c) Plot the supply line currents and phase voltages phasorally.arrow_forwardTHESE ARE THE QUESTIONS FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS AND THE CHAPTER IS PERFORMANCE OF TRANSMISSION LINES AND THE TOPIC IS SHORT TRANSMISSION LINES THE ANSWERS ARE GIVEN WITH THE QUESTION PLEASE DO ALL THE QUESTIONS PROPERLY „DONOT SKIP ANY STEP AND DO YOUR BEST 4.) Estimate the distance over which a load of 15000 kW at 0-85 p.f. can be delivered by a 3-phase transmission line having conductors of steel-cored aluminium each of resistance 0-905 O/phase per kilometre. The voltage at the receiving end is to be 132 kV and the loss in transmission is to be 7-5% of the load. [69-55 km] 5). A 3-phase line 3 km long delivers 3000 kw at a p.f. 0-8 lagging to a load. The resistance and reactance per km of each conductor are 0-40 and 0-3 Q respectively. If the voltage at the supply end is maintained at 11 kv, calculate: (i) ceceiving end voltage (line-to-line) (ii) line current (ii) transmission efficiency. [(i) 10.46 kv (ii) 207 A (ii) 95%] 6). A short 3-0 transmission line with an…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License