Concept explainers
A three-phase system is constructed from a balanced Y-connected source operating at 50 Hz and having a line voltage of 210 V, and each phase of the balanced load draws 130 W at a leading power factor of 0.75. (a) Calculate the line current and the total power supplied to the load. (b) If a purely resistive load of 1 Ω is connected in parallel with each existing load, calculate the new line current and total power supplied to the load. (c) Verify your answers using appropriate simulations.
Want to see the full answer?
Check out a sample textbook solutionChapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Additional Engineering Textbook Solutions
Programmable Logic Controllers
Electric machinery fundamentals
Electric Circuits. (11th Edition)
Basic Engineering Circuit Analysis
Introductory Circuit Analysis (13th Edition)
Electric Circuits (10th Edition)
- Please answer quickly "In series-connected ac circuit, the total voltage across the circuit is always equal to the sum of the magnitude (only) of the individual voltage across each element." True False The power factor is equal to cosine of the phase difference. True False A leading power factor means that the circuit is predominantly capacitive in nature. True False "Since most loads are resistive in nature (e.g. motors), improvement of power factor is done by connecting capacitor banks or a synchronous condenser " True Falsearrow_forwardAnalyze the:Figure Q2(a) Impedance seen by the source.(b) Coupling coefficient, K when angular frequency, ω = 4 rad/s .(c) Current through booth impedance 4 Ω, I1 and I2.arrow_forwardA 3-phase load consists of three similar inductive coils, each of resistance 50Ω and inductance 0.3 H. The supply is 415 V, 50 Hz, Calculate (a) the line current (b) the power factor and (c) the total power when the load is (i) star-connected and (ii) delta-connected.arrow_forward
- Two balanced Y-connected loads, one drawing 10 kW at 0.8 power factor lagging and the other IS kW at 0.9 power factor leading, are connected in parallel and supplied by a balanced three-phase Y-connected, 480-V source. (a) Determine the source current. (b) If the load neutrals are connected to the source neutral by a zero-ohm neutral wire through an ammeter, what will the ammeter read?arrow_forwardDetermine a. total impedance b.,. current Ip and c. total power drawn by the circuitarrow_forward(b) AC circuit analysis is the process of determining the currents and voltages in a network of connected components. By using Source Transformation method for the following circuit in Figure 2, estimate: i. The current flow through Z, I, where Z is 3 + j6 ohm ii. The condition of current flow through Z, I, whether it is leading or lagging the supply current, 520° A and the phase difference. 5/0° A -1202 j4 92 m -j4Q2 Figure 2 Harrow_forward
- a)Determine the current i2 for the circuit given below B)for a delta connected system prove that line current lags the phase current by an angle 30° and also draw the complete phasor diagramarrow_forward3. In a R-C parallel circuit, total current is out of phase with the applied voltage. True False 5. In a R-C series circuit, total current is out of phase with the applied voltage. True False 6. In series-connected ac circuit, the value of the equivalent admittance of the circuit is equal to the reciprocal of phasor sum of the reciprocal of the individual admittances. True Falsearrow_forwardThree inductive loads each of resistance 75Ω and inductance 318.4mH are connected in delta to a 415V, 50 Hz, 3-phase supply. Determine (a) the phase voltage, (b) the phase current, and (c) the line current. [(a) 415V (b) 3.32A (c) 5.75A]arrow_forward
- A three-phase load consists of three similar inductive coils, each of resistance 50 and inductance 0.3H. The supply is 415V, 50 Hz. Calculate: (i) the line current (ii) the power factor (iii) the total power when the load is (A) star-connected and (B) delta-connected.arrow_forwardA 40 Ω resistor and a 10 mH coil are in parallel across an 80 V, 500 Hz ac line. Find the (a) branch currents (b) total current (c) phase angle (d) impedance (e) power drawn.arrow_forwardA 40 ohms resistor and a 10 mH coild are in parallel across an 80 V, 500 Hz ac line. Find the (a) branch currents (b) total current (c) phase angle (d) impedance (e) power drawn Please answer ASAP thank youarrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning